Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-175-16L
- Bel Signal Transformer
-
20:
$82.97
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-175-16L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$82.97
|
|
|
$80.72
|
|
|
$78.81
|
|
|
$77.79
|
|
|
View
|
|
|
Quote
|
|
Min.: 20
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
16 V CT/8 V
|
175 VA
|
11 A/22 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
79.7 mm
|
95.3 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-175-20L
- Bel Signal Transformer
-
20:
$81.00
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-175-20L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$81.00
|
|
|
$78.81
|
|
|
$76.93
|
|
|
$75.95
|
|
|
View
|
|
|
Quote
|
|
Min.: 20
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
20 V CT/10 V
|
175 VA
|
8.8 A/17.6 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
79.7 mm
|
95.3 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-175-230L
- Bel Signal Transformer
-
20:
$96.68
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-175-230L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$96.68
|
|
|
$90.35
|
|
|
$88.19
|
|
|
$81.68
|
|
|
View
|
|
|
Quote
|
|
Min.: 20
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
230 V CT/115 V
|
175 VA
|
760 mA/1.52 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
79.7 mm
|
95.3 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-175-24L
- Bel Signal Transformer
-
1:
$113.27
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-175-24L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$113.27
|
|
|
$101.23
|
|
|
$96.47
|
|
|
$93.68
|
|
|
View
|
|
|
$91.55
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
24 V CT/12 V
|
175 VA
|
7.3 A/14.6 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
79.7 mm
|
95.3 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-175-36L
- Bel Signal Transformer
-
20:
$97.31
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-175-36L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$97.31
|
|
|
$94.67
|
|
|
$92.03
|
|
|
$92.02
|
|
|
Quote
|
|
|
Quote
|
|
Min.: 20
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
36 V CT/18 V
|
175 VA
|
4.8 A/9.6 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
79.7 mm
|
95.3 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-25-10L
- Bel Signal Transformer
-
60:
$23.11
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-10L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
Min.: 60
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
10 V CT/5 V
|
25 VA
|
2.5 A/5 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-25-12L
- Bel Signal Transformer
-
60:
$23.51
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-12L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
Min.: 60
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
12.6 V CT/6.3 V
|
25 VA
|
2 A/4 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-25-16L
- Bel Signal Transformer
-
1:
$30.22
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-16L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$30.22
|
|
|
$26.66
|
|
|
$24.74
|
|
|
$23.11
|
|
|
$22.21
|
|
Min.: 1
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
16 V CT/8 V
|
25 VA
|
1.6 A/3.2 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-25-20L
- Bel Signal Transformer
-
60:
$23.35
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-20L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
Min.: 60
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
20 V CT/10 V
|
25 VA
|
1.25 A/2.5 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-25-24L
- Bel Signal Transformer
-
1:
$30.44
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-24L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$30.44
|
|
|
$26.86
|
|
|
$24.92
|
|
|
$23.27
|
|
|
$22.38
|
|
Min.: 1
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
24 V CT/12 V
|
25 VA
|
1 A/2 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer
- A41-25-28
- Bel Signal Transformer
-
1:
$32.69
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-28
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$32.69
|
|
|
$28.66
|
|
|
$27.21
|
|
|
$26.13
|
|
|
View
|
|
|
$25.34
|
|
|
$24.90
|
|
|
$24.07
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
28 V CT/14 V
|
25 VA
|
900 mA/1.86 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-25-28L
- Bel Signal Transformer
-
60:
$23.42
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-28L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
Min.: 60
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
28 V CT/14 V
|
25 VA
|
900 mA/1.86 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-25-36L
- Bel Signal Transformer
-
60:
$23.54
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-36L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
Min.: 60
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
36 V CT/18 V
|
25 VA
|
700 mA/1.4 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer
- A41-25-512
- Bel Signal Transformer
-
60:
$23.94
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-512
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
Min.: 60
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
5 V/12 V
|
25 VA
|
150 mA/1.25 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer
- A41-25-515
- Bel Signal Transformer
-
60:
$25.95
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-25-515
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
Min.: 60
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
5 V/15 V
|
25 VA
|
130 mA/1.25 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
71.4 mm
|
54.4 mm
|
58.7 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer
- A41-43-10
- Bel Signal Transformer
-
40:
$32.19
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-10
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$32.19
|
|
|
$31.45
|
|
|
$31.06
|
|
|
$31.05
|
|
|
Quote
|
|
|
Quote
|
|
Min.: 40
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
10 V CT/5 V
|
43 VA
|
4.3 A/8.6 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-43-10L
- Bel Signal Transformer
-
1:
$42.26
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-10L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$42.26
|
|
|
$39.53
|
|
|
$31.89
|
|
|
$31.80
|
|
|
Quote
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
10 V CT/5 V
|
43 VA
|
4.3 A/8.6 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-43-12L
- Bel Signal Transformer
-
40:
$31.77
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-12L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$31.77
|
|
|
$29.09
|
|
|
$28.86
|
|
|
$28.80
|
|
|
Quote
|
|
|
Quote
|
|
Min.: 40
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
12.6 V CT/6.3 V
|
43 VA
|
3.4 A/6.8 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer
- A41-43-16
- Bel Signal Transformer
-
1:
$42.01
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-16
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$42.01
|
|
|
$34.61
|
|
|
$32.05
|
|
|
$30.10
|
|
|
View
|
|
|
$29.43
|
|
|
$29.32
|
|
Min.: 1
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
16 V CT/8 V
|
43 VA
|
2.7 A/5.4 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-43-16L
- Bel Signal Transformer
-
40:
$30.86
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-16L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$30.86
|
|
|
$28.81
|
|
|
$27.71
|
|
Min.: 40
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
16 V CT/8 V
|
43 VA
|
2.7 A/5.4 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer
- A41-43-20
- Bel Signal Transformer
-
1:
$42.20
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-20
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$42.20
|
|
|
$41.51
|
|
|
$33.29
|
|
|
$32.56
|
|
|
View
|
|
|
$31.95
|
|
|
$31.23
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
|
115 VAC, 230 VAC
|
20 V CT/10 V
|
43 VA
|
2.2 A/4.4 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-43-20L
- Bel Signal Transformer
-
40:
$32.78
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-20L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$32.78
|
|
|
$32.00
|
|
|
$31.60
|
|
|
Quote
|
|
|
Quote
|
|
Min.: 40
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
20 V CT/10 V
|
43 VA
|
2.2 A/4.4 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-43-230L
- Bel Signal Transformer
-
40:
$33.96
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-230L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$33.96
|
|
|
$33.12
|
|
|
$32.49
|
|
|
$32.48
|
|
|
Quote
|
|
|
Quote
|
|
Min.: 40
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
230 V CT/115 V
|
43 VA
|
190 mA/380 mA
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-43-24L
- Bel Signal Transformer
-
40:
$30.62
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-24L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$30.62
|
|
|
$28.59
|
|
|
$27.48
|
|
Min.: 40
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
24 V CT/12 V
|
43 VA
|
1.8 A/3.6 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|
|
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
- A41-43-28L
- Bel Signal Transformer
-
40:
$31.99
-
Non-Stocked Lead-Time 18 Weeks
|
Mouser Part No
530-A41-43-28L
|
Bel Signal Transformer
|
Power Transformers 50\60 Hz, Laminated Transformer w/ lead wires
|
|
Non-Stocked Lead-Time 18 Weeks
|
|
|
$31.99
|
|
|
$31.25
|
|
|
$30.86
|
|
|
$30.85
|
|
Min.: 40
Mult.: 20
|
|
|
115 VAC, 230 VAC
|
28 V CT/14 V
|
43 VA
|
1.5 A/3 A
|
Chassis
|
Dual Primary Winding
|
Dual Secondary Winding
|
79.4 mm
|
54.4 mm
|
68.2 mm
|
A41
|
|